Difference between revisions of "Unit heat consumption of buildings in Finland"

From Testiwiki
Jump to: navigation, search
Line 11: Line 11:
  
 
== Answer ==
 
== Answer ==
 +
 +
<t2b name="U.factor" index="Surface,Construction year,Unit" desc="Kuvaus" unit="-">
 +
Outside wall|<1960|W/(m2K)|0.48|
 +
Outside wall|1960|W/(m2K)|0.40|
 +
Outside wall|1970|W/(m2K)|0.30|
 +
Outside wall|1980|W/(m2K)|0.28|
 +
Outside wall|1990|W/(m2K)|0.28|
 +
Outside wall|2000|W/(m2K)|0.0.25|
 +
Outside wall|2010|W/(m2K)|0.17|
 +
Roof|<1960|W/(m2K)|0.30|
 +
Roof|1960|W/(m2K)|0.28|
 +
Roof|1970|W/(m2K)|0.25|
 +
Roof|1980|W/(m2K)|0.25|
 +
Roof|1990|W/(m2K)|0.16|
 +
Roof|2000|W/(m2K)|0.16|
 +
Roof|2010|W/(m2K)|0.09|
 +
Floor|<1960|W/(m2K)|0.30|
 +
Floor|1960|W/(m2K)|0.30|
 +
Floor|1970|W/(m2K)|0.30|
 +
Floor|1980|W/(m2K)|0.30|
 +
Floor|1990|W/(m2K)|0.30|
 +
Floor|2000|W/(m2K)|0.25|
 +
Floor|2010|W/(m2K)|0.25|
 +
Window|<1960|W/(m2K)|2.1|
 +
Window|1960|W/(m2K)|1.9|
 +
Window|1970|W/(m2K)|1.6|
 +
Window|1980|W/(m2K)|1.4|
 +
Window|1990|W/(m2K)|1.4|
 +
Window|2000|W/(m2K)|1.4|
 +
Window|2010|W/(m2K)|1|
 +
Outer door|<1960|W/(m2K)|1.4|
 +
Outer door|1960|W/(m2K)|1.4|
 +
Outer door|1970|W/(m2K)|1.4|
 +
Outer door|1980|W/(m2K)|1.4|
 +
Outer door|1990|W/(m2K)|1.4|
 +
Outer door|2000|W/(m2K)|1.4|
 +
Outer door|2010|W/(m2K)|1|
 +
</t2b>
 +
 +
 +
 +
<rcode graphics="1"
 +
>
 +
 +
library(OpasnetUtils)
 +
library(ggplot2)
 +
 +
objects.latest('Op_fi2808','alustus')
 +
 +
 +
altistuminen <- EvalOutput(altistuminen)
 +
 +
 +
altistuminen@output$altistuminenSource <- NULL
 +
 +
altistuminen@output <- reshape(
 +
altistuminen@output,
 +
timevar = "Ikä",
 +
idvar = c("Altiste", "Altistumistaso", "Altistumislähde"),
 +
direction = "wide"
 +
)
 +
 +
colnames(altistuminen@output) <- gsub("altistuminenResult.", "", colnames(altistuminen@output))
 +
 +
cat("Keskimääräinen päivittäinen haitta-aineen saanti paikallisista lähteistä (µg/kg/d) sekä kokonaissaanti (paikalliset lähteet ja taustasaanti ravinnosta, µg/kg/vrk).\n")
 +
oprint(altistuminen@output[altistuminen@output$Altiste == altiste, ],digits=5)
 +
 +
</rcode>
 +
  
  

Revision as of 12:41, 23 May 2013


Question

What is the average unit heat consumption (energy purchase, kWh/m2/year) of different types of residential buildings in Finland?

Characterisation of buildings:

  • Building type (detached house, row house, apartment building)
  • Construction decade
  • Primary heat source (light oil, pellet, district heat, electricity, geothermal)

Answer

U.factor(-)
ObsSurfaceConstruction yearUnitResultKuvaus
1Outside wall<1960W/(m2K)0.48
2Outside wall1960W/(m2K)0.40
3Outside wall1970W/(m2K)0.30
4Outside wall1980W/(m2K)0.28
5Outside wall1990W/(m2K)0.28
6Outside wall2000W/(m2K)0.0.25
7Outside wall2010W/(m2K)0.17
8Roof<1960W/(m2K)0.30
9Roof1960W/(m2K)0.28
10Roof1970W/(m2K)0.25
11Roof1980W/(m2K)0.25
12Roof1990W/(m2K)0.16
13Roof2000W/(m2K)0.16
14Roof2010W/(m2K)0.09
15Floor<1960W/(m2K)0.30
16Floor1960W/(m2K)0.30
17Floor1970W/(m2K)0.30
18Floor1980W/(m2K)0.30
19Floor1990W/(m2K)0.30
20Floor2000W/(m2K)0.25
21Floor2010W/(m2K)0.25
22Window<1960W/(m2K)2.1
23Window1960W/(m2K)1.9
24Window1970W/(m2K)1.6
25Window1980W/(m2K)1.4
26Window1990W/(m2K)1.4
27Window2000W/(m2K)1.4
28Window2010W/(m2K)1
29Outer door<1960W/(m2K)1.4
30Outer door1960W/(m2K)1.4
31Outer door1970W/(m2K)1.4
32Outer door1980W/(m2K)1.4
33Outer door1990W/(m2K)1.4
34Outer door2000W/(m2K)1.4
35Outer door2010W/(m2K)1


+ Show code


Rationale

Heat consumption of a building depends on the outdoor air temperature, preferred indoor air temperature, insulation, air tightness and surface area of the building envelope (walls, roof, floor, windows, doors), ventilation rate and heat recovery from the ventilated air, heating system (efficiency of heat production and recovery of lost heat), hot water demand, internal heat gains from people and electrical equipment, and external heat gains from the sun.

Models for calculating building heat consumption

Outdoor temperature in Finland

  • Finnish Meteorological Institute temperature statistics[3]:
    • Monthly temperatures (Celsius) in different observation points in Finland in 1971-2000
    • Areas (Southern Finland, Western Finland, Eastern Finland, Northern Finland) are defined based on Statistics Finland major regions classification[4]
    • The average monthly temperature in each area has been calculated as the mean of all the observation points (cities) within that area.
Area/City January February March April May June July August September October November December Average for September-May
Southern Finland
Kaarina (Yltöinen) -4.6 -5.5 -1.9 3.1 9.6 14.4 16.9 15.3 10.4 5.7 1 -2.8 1.7
Helsinki-Vantaa (airport) -5.2 -5.7 -2.2 3.3 10 14.6 16.9 15.3 10.1 5.2 0.1 -3.2 1.4
Lahti (Laune) -6.8 -7.3 -2.9 2.8 9.9 14.6 16.6 14.6 9.1 4.2 -0.8 -4,8 0.4
Lappeenranta (airport) -8 -8.1 -3.2 2.5 9.9 14.7 17.2 14.9 9.4 3.9 -1.4 -5.2 0
Average -6.2 -6.7 -2.6 2.9 9.9 14.6 16.9 15.0 9.8 4.8 -0.3 -4.0 0.9
Western Finland
Tampere-Pirkkala (airport) -6.7 -7 -2.8 3 9.5 14.4 16.6 14.6 9.4 4.7 -1 -4.6 0.5
Jyväskylä (airport) -8.5 -8.7 -4 1.4 8.7 14 16 13.7 8.2 3.2 -2.2 -6.4 -0.9
Seinäjoki (Pelmaa) -7.1 -7.3 -3.2 2.2 8.8 13.9 15.4 13.8 8.7 3.9 -1.4 -5.3 -0.1
Average -7.4 -7.7 -3.3 2.2 9.0 14.1 16.0 14.0 8.8 3.9 -1.5 -5.4 -0.2
Eastern Finland
Tohmajärvi (Kemie) -10 -9.8 -4.4 1.3 8.6 14 16.1 13.5 8.2 3 -2.9 -7.3 -1.5
Valtimo (Kk) -11.1 -10.8 -5 0.6 8 13.7 16 13.3 7.8 2.3 -3.7 -8.7 -2.3
Siikajoki -9.4 -9 -4.4 1 7.6 13.1 15.5 13 7.9 2.8 -3.1 -7.3 -1.5
Average -10.2 -9.9 -4.6 1.0 8.1 13.6 15.9 13.3 8.0 2.7 -3.2 -7.8 -1.8
Northern Finland
Rovaniemi (airport) -11.7 -11.0 -6.1 -1.0 5.8 12.2 14.9 12.1 6.6 0.2 -6.1 -10.0 -3.7
  • Jylhä et al. 2009[5]
    • Estimates for climate change in Finland by the Finnish Meteorologigal Institute.
    • Projected change in seasonal and annual mean temperature (Celsius) in 2010-2039 relative to 1971-2000 as averaged over the territory of Finland. In addition to the best estimate (50%), six other percentiles of the probability distribution are given. The projection is based on the simulations performed with 19 global climate models, with IPCC greenhouse gas emission scenarios A1B, A2 and B1 considered equally likely.
Probability distribution percentile: 5 % 10 % 25 % 50 % 75 % 90 % 95 %
Winter 1.1 1.4 1.8 2.2 2.7 3.1 3.3
Spring 0.4 0.6 1 1.4 1.9 2.3 2.5
Summer 0 0.3 0.6 1.1 1.5 1.9 2.1
Autumn 0.6 0.8 1.1 1.4 1.7 2 2.2
Annual 0.7 0.9 1.2 1.5 1.9 2.2 2.3

Indoor air temperature

  • Finnish health based guideline values (Celsius degrees) for indoor air temperature in residential buildings[6]:
    • Good level: 21 C
    • Lowest acceptable level: 18 C
    • Highest acceptable level: 26 C
    • Highest recommended level during heating period: 23-24 C

Building characteristics

  • Building structure U-values (heat transfer coefficient, W / m2 K) given in Finnish building regulations:
1978-1985 1985-2002 2003-2006 2007-2010 2010-
Building structure Mass less than 100 kg / m2 Mass over 100 kg / m2 Warm area > 17 °C Half warm area > 5 °C Warm area > 17 °C Half warm area > 5 °C Warm area 17 °C Half warm area > 5 °C Warm area 17 °C Half warm area > 5 °C
Wall 0,29 0,35 0,28 0,45 0,25 0,45 0,24 0,38 0,17 0,26
Roof 0,23 0,29 0,22 0,45 0,16 0,45 0,15 0,28 0,09 0,14
Floor 0,23 0,29 0,22 0,45 0,16 0,45 0,15 0,28 0,09 0,26
Floor structure directly against ground 0,4 0,4 0,36 0,45 0,25 0,45 0,24 0,34 0,16 0,24
Window 2,1 3,1 1,4 2,1 1,4 1,8 1 1,4
Door 0,7 2,9 1,4 2,1 1,4 1,8 1 1,4
  • Development of building characteristics in Finland[7]
50's 60's 70's 80's New (2009), standard New (2009), tight
Roof, U-value 0.3 0.28 0.25 0.25 0.16 0.16
Floor, U-value 0.3 0.3 0.3 0.3 0.2 0.2
Wall, U-value 0.48 0.4 0.3 0.28 0.25 0.25
Window, U-value 2.1 2.1 1.6 1.4 1.4 1.4
n50 (air leakage) 12 10 7 7 4 1
Air exchange technique Gravitational Gravitational Mechanical Mechanical Mechanical with heat recovery Mechanical with heat recovery
  • Window surface area in the 2010 Finnish building regulations[8]
    • The guideline value (vertailuarvo) for the total surface area of windows is 15% from the total surface area of floors completely or partly above the ground level.
    • The maximum value for the total surface area of windows is 50% from the total surface area of the outside walls.

Warm water consumption

Dependencies

  • Outdoor air temperature
  • Indoor air temperature
  • Building envelope (walls, roof, floor, windows, doors)
    • Insulation (heat conductance)
    • Air tightness (involuntary air leakage)
  • Air ventilation (rate, heat recovery)
  • Heating system (heat production efficiency and heat loss from distribution within a building)
  • Internal heat gains (electrical equipment, people, recovery of heat loss from heat distribution within a building)
  • External heat gains (sun)
  • Hot water demand

Formula

See also

Keywords

Building, heat consumption

References

Related files

<mfanonymousfilelist></mfanonymousfilelist>

Unit heat consumption of buildings in Finland. Opasnet . [1]. Accessed 26 Jun 2024.