Question
What is the building stock in Basel?
Answer
Rationale
Data
Detailed data can be found from heande:Buildings in Basel. This data is aggregated to the postal code level. The table uses Swiss Land Survey coordinates CH1903. [1] [2] Use this code in the ova2spat function:
proj4string = "+init=epsg:21781"
Renovations
Estimates from Laura Perez and Stephan Trüeb, unibas.ch N:\YMAL\Projects\Urgenche\WP9 Basel\Energy_scenarios_Basel_update.docx
Obs | Age | Result | Description |
---|---|---|---|
1 | 0 | 0 | Estimates from Laura Perez and Stephan Trüeb |
2 | 20 | 0 | Assumption Result applies to buildings older than the value in the Age column. |
3 | 25 | 1 | |
4 | 30 | 1 | |
5 | 50 | 1 | |
6 | 100 | 1 | |
7 | 1000 | 1 |
Obs | Renovation | Fraction | Description |
---|---|---|---|
1 | None | 0 | |
2 | Windows | 65 | |
3 | Technical systems | 30 | |
4 | Sheath reform | 5 | |
5 | General | 0 |
Emission locations
Where and how do the emissions of heating take place?
Obs | Heating | Emission site | Emission height | Dummy |
---|---|---|---|---|
1 | District | 4056 | High | 4056 is the postal code of the heat and power plant IWB, Hagenaustrasse 40/70 4056 Basel. |
2 | Long-distance heating | 4056 | High | |
3 | Electricity | 4056 | High | |
4 | Geothermal | 4056 | High | |
5 | Centrifuge, hydro-extractor | 4056 | High | |
6 | Heating oil | At site of consumption | Ground | |
7 | Wood | At site of consumption | Ground | |
8 | Gas | At site of consumption | Ground | |
9 | Coal | At site of consumption | Ground | |
10 | Solar heater/ collector | At site of consumption | Ground | |
11 | No energy source | At site of consumption | Ground | |
12 | Other sources | At site of consumption | Ground |
Obs | Postal code | X | Y |
---|---|---|---|
1 | 4001 | 611296.55 | 267316.04 |
2 | 4051 | 611004.37 | 267137.18 |
3 | 4052 | 612735.06 | 266596.60 |
4 | 4053 | 611695.00 | 265635.41 |
5 | 4054 | 609694.31 | 266598.91 |
6 | 4055 | 609798.12 | 267812.13 |
7 | 4056 | 610271.78 | 268500.37 |
8 | 4057 | 611580.35 | 268976.81 |
9 | 4058 | 612781.70 | 268225.32 |
10 | 4059 | 611615.85 | 264689.04 |
11 | 4125 | 615721.84 | 269737.40 |
12 | 4126 | 617160.01 | 268852.20 |
Fuel use by heating type
Basel-specific data about connections between Heating and fuel usage. Generic data should be taken from Energy balance.
Obs | Heating | Burner | Fuel | Fraction | Description |
---|---|---|---|---|---|
1 | Long-distance heating | Large fluidized bed | Waste | 0.5 | The values are from Wikipedia for Basel. See below. |
2 | Long-distance heating | Large fluidized bed | Wood | 0.1 | |
3 | Long-distance heating | Large fluidized bed | Gas | 0.4 | |
4 | Long-distance heating | Grid | Electricity | 0 | This is geothermally-generated district heating. Note: the fraction you need electricity is ca. 0.3*the amount of geoheat produced. |
5 | Coal | Large fluidized bed | Coal | 1 |
For guesstimates about Long-distance heating (which is used in Basel), see Climate change policies in Basel and de:IWB.
Calculations
This code creates ovariables that are needed to run the Building model and its ovariables buildings and heatingEnergy.
See also
References