Buildings in Basel: Difference between revisions

From Opasnet
Jump to navigation Jump to search
(→‎Calculations: initiation code works)
Line 38: Line 38:


# [[Buildings in Basel]], building stock, locations by postal codes (in A Swiss coordinate system)
# [[Buildings in Basel]], building stock, locations by postal codes (in A Swiss coordinate system)
buildingStock <- Ovariable("buildingStock", ddata = "Op_en7044.postal_code_areas")
stockBuildings <- Ovariable("stockBuildings", ddata = "Op_en7044.postal_code_areas")
colnames(stockBuildings@data)[colnames(stockBuildings@data) == "Eventyear"] <- "Time"


# Geolocations of the buildings for emission calculations.
# Geolocations of the buildings for emission calculations.
Line 53: Line 54:
))
))


buildingTypes <- 1 # A dummy variable to combine two different indices: Building and Building2
changeBuildings <- 0
constructionAreas <- 1 #Places where construction takes place.
obstime <- data.frame(Startyear = 2010)
efficiencies <- Ovariable("efficiencies", data = data.frame(Efficiency = "New", Result = 1)) # Current efficiencies
heating_before <- TRUE # Should heatingShares be calculated before renovate and timepoints (or after)?
efficienciesNew <- 0 # Energy efficiencies in the future
efficiency_before <- TRUE # Should efficiencyShares be calculated before renovate and timepoints (or after)?
eventyear <- 1 # A dummy variable to combine time periods to numerical time axis.
efficiencyShares <- Ovariable("efficiencies", data = data.frame(Efficiency = "New", Result = 1)) # Current efficiencies
heatingShares <- 1 # Heating types of current buildings. Exists as part of buildingStock
heatingShares <- 1 # Heating types of current buildings. Exists as part of buildingStock
heatingSharesNew <- 0 # Heating types of the buildings in the future
heatingSharesNew <- 0 # Heating types of the buildings in the future
renovation <- 0 # Percentage of renovations per year
renovationRate <- 0 # Percentage of renovations per year
renovationShares <- 0 # Fraction of renovation type when renovation is done. Renovations not considered.
renovationShares <- 0 # Fraction of renovation type when renovation is done. Renovations not considered.


Line 66: Line 67:
# obsyear, # Years for which observations are calculated. Must be given in an assessment.
# obsyear, # Years for which observations are calculated. Must be given in an assessment.


openv.setN(0)
if(FALSE) {
objects.store(
objects.store(
buildingStock, # Current building stock
buildingStock, # Current building stock
Line 93: Line 99:
renovationShares # Fraction of renovation type when renovation is done.
renovationShares # Fraction of renovation type when renovation is done.
stored.\n")
stored.\n")
 
}
</rcode>
</rcode>



Revision as of 13:24, 19 February 2015



Question

What is the building stock in Basel?

Answer

Rationale

Detailed data can be found from heande:Buildings in Basel. This data is aggregated to the postal code level. The table uses Swiss Land Survey coordinates CH1903. [1] [2] Use this code in the ova2spat function:

proj4string = "+init=epsg:21781"
Locations of postal codes(epsg:21781)
ObsPostal codeXY
14001611296.55267316.04
24051611004.37267137.18
34052612735.06266596.60
44053611695.00265635.41
54054609694.31266598.91
64055609798.12267812.13
74056610271.78268500.37
84057611580.35268976.81
94058612781.70268225.32
104059611615.85264689.04
114125615721.84269737.40
124126617160.01268852.20

Calculations

This code creates ovariables that are needed to run the Building model and its ovariables buildings and heatingEnergy.

+ Show code

See also

Urgenche research project 2011 - 2014: city-level climate change mitigation
Urgenche pages

Urgenche main page · Category:Urgenche · Urgenche project page (password-protected)

Relevant data
Building stock data in Urgenche‎ · Building regulations in Finland · Concentration-response to PM2.5 · Emission factors for burning processes · ERF of indoor dampness on respiratory health effects · ERF of several environmental pollutions · General criteria for land use · Indoor environment quality (IEQ) factors · Intake fractions of PM · Land use in Urgenche · Land use and boundary in Urgenche · Energy use of buildings

Relevant methods
Building model · Energy balance · Health impact assessment · Opasnet map · Help:Drawing graphs · OpasnetUtils‎ · Recommended R functions‎ · Using summary tables‎

City Kuopio
Climate change policies and health in Kuopio (assessment) · Climate change policies in Kuopio (plausible city-level climate policies) · Health impacts of energy consumption in Kuopio · Building stock in Kuopio · Cost curves for energy (prioritization of options) · Energy balance in Kuopio (energy data) · Energy consumption and GHG emissions in Kuopio by sector · Energy consumption classes (categorisation) · Energy consumption of heating of buildings in Kuopio · Energy transformations (energy production and use processes) · Fuels used by Haapaniemi energy plant · Greenhouse gas emissions in Kuopio · Haapaniemi energy plant in Kuopio · Land use in Kuopio · Building data availability in Kuopio · Password-protected pages: File:Heat use in Kuopio.csv · Kuopio housing

City Basel
Buildings in Basel (password-protected)

Energy balances
Energy balance in Basel · Energy balance in Kuopio · Energy balance in Stuttgart · Energy balance in Suzhou


References


Related files