Energy consumption of Bioher plant
| Moderator:Pauliina (see all) |
|
|
| Upload data
|
Scope
Total heating consumption by plant in Bioher. Analytica model can be found here.
Definition
Data
Table 1. Proportion of fuel type in own heating (description in: Heating systems in buildings in Finland)
| Fuel type | Proportion |
| Own | 0.34 |
| Electricity | 0.28 |
| District | 0.38 |
Table 2. Energy efficiency of plant energy production by fuel type.
| Fuel type of plant | Efficiency |
| Heavy oil | 0.9 |
| Wood chips | 0.7 |
| Geothermal | 0 |
| Other | 0 |
Table 3. Fraction of fuel type used in plant
| Fuel type of plant | Fraction |
| Heavy oil | 0.5 |
| Wood chips | 0.3 |
| Geothermal | 0.1 |
| Other | 0.1 |
Causality
Upstream variables:
Calculation is based on method that is reported in Heating consumption of buildings and on variable presented in Floor area in Bioher.
Downstream variables:
Unit
kWh/year
Formula
<anacode>var a:= Floor_area_in_bioher[fuel='District']+Floor_area_in_bioher[fuel='Other']*Fuel_type_of_other[Fuel_type_of_other='District']; a*Total_heating_consum*Efficiency_by_fuel_t*Fraction_of_fuel_typ</anacode>
Result
Table 4. Total heating consumption (kWh/year) by plant heating in Bioher.
| Heavy oil | Wood chips | Total | |
|---|---|---|---|
| Detached house | 932262 | 435055 | 1367317 |
| Row house | 1404693 | 655523 | 2060216 |
| Block house | 7177040 | 3349285 | 10526325 |
| Total | 9513994 | 4439864 | 13953858 |
See also
References
Will appear here automatically, if cited above using the <ref></ref> tags. Additional references can also be listed here.